Latest News & Events

latest-news

Virtual instrumentation

2016-05-02

 

Winlog SCADA HMI Software

Realistic rendering of panel instrumentation provides remote users with an instant check of the variables to monitor. For this purpose we have introduced in our Winlog Pro SCADA software the popular library of animated graphic objects Industrial Gadgets ActiveX Basic Edition with lots of animated digital (buttons, switches, leds) and numeric objects (pointer indicators, potentiometrs, led displays).
latest-news

SCADA software Winlog is renewed

2016-04-13

 

Winlog SCADA HMI Software

Sielco Sistemi is pleased to announce that the new version 3.01 of SCADA software Winlog Pro is now available. The new version represents a real revolution in terms of look, functionality and performance.

We have re-designed the whole SCADA software platform to take advantage of new technologies, while maintaining the original robustness and reliability and ensuring the almost complete compatibility with previously developed applications.

The product has a more up-to-date and appealing look; all icons are in Pure Flat 2013 style and access to various functions and development tools is now more easy and intuitive.

We have revised all development tools, in order to increase performance and make it easier to use. A special effort was made to improve graphics, increasing the number of supported formats (JPG, PNG, GIF, …), enhancing transparency options, making it smoother motion graphics.

In addition to the graphic library Symbol Factory, development tools include the popular libraries of animated graphic objects Industrial Gadgets ActiveX Basic Edition and Industrial Gadgets ActiveX PRO Edition, with lots of animated objects digital (buttons, switches, leds), numeric (pointer indicators, potentiometrs, led displays) and complex (motors, pumps, valves, tanks, pipes).

All communication drivers have been revised, in order to uniform the configuration of the various protocols. New communication protocols were also included, such as M-Bus protocol and Mitsubishi MELSEC.

Version 3.01 makes available remote control via TeamViewer technology. By a simple “click” on the icon “Quick Support”, the user will allow the Sielco Sistemi support team to provide remote control and technical assistance through Internet.

Winlog Pro now includes a new web server support which conforms the graphical object properties to those of the standard version and provides a more fast and safe data exchange between client and server. Clients can access the server via new passwords for sending commands and write data. Web server support is now available with the free demo version of Winlog Lite.

Finally it should be noted that version 3.01 of SCADA software Winlog Pro makes it available new and even more convenient development and runtime licenses.

 

latest-news

Sielco Sistemi – The new Sistemi Sielco website is online!

2016-04-07

 

New Winlog SCADA website

The Sielco Sistemi website has been completely renewed in graphics and contents. The new website features a modern and attractive layout with a mobile responsive design.

Sielco Sistemi was created from the original group that in the early '90 has developed the software package for automation Winlog and now is offering its renewed and enhanced version Winlog Pro. Our mission is to promote the diffusion of the SCADA software Winlog Pro all over the world through the continuous updating and enrichment of the product, the close cooperation with our customers and Solution Providers and the expansion and strengthening of our distribution network. In addition to Winlog Pro SCADA software, we offer a range of industrial Panel PCs (PClog) and a Data Acquisition System (IOlog). Sielco Sistemi also offers itself as a partner for the development of applications and the implementation of integrated hardware/software solutions.

Our know-how comes from direct experience gained in over twenty years of fieldwork. Among our customers are machine manufacturers, production managers, engineering companies and electrical installers. We have provided systems for supervision of industrial plants, for acquisition and processing of production data, for quality control of production and storing process, for building automation, for remote control of public utility networks. We have gained specific skills in several industrial sectors as textiles, plastics, food, ceramics and electronics.

Sensitivity to our customer’s needs is the most distinctive feature of the way we do business. We are committed to work closely with our customers, to find a common language, understand their specific problems and provide timely responses and solutions. Our services: training and upgrading courses, consultancy in the design phase, development of the project, assistance during start-up, after-sales support and technical assistance contracts.

 

Other News

other-news

Remote test of IOlog modules

2015-09-07

Users and developers can test IOlog data acquisition modules thanks to a test system, which can be accessed at address iolog.sielcosistemi.com using Modbus TCP protocol on port 502.Click here to view the page. By this way you can directly communicate with remote IOlog modules using your own supervisory software or your own PLC. You can also download the software Winlog Lite and run the project Circuit Demo.Click here to view the guide. System is designed to provide feedback to the user, so you can verify that commands sent have been executed. Digital outputs of module SS3130 are wired to the digital inputs of SS3148; analog outputs of module SS3024 are wired to the analog inputs of SS3017-I. Furthermore four thermocouple sensors, which measure the environmental temperature, are connected to module SS3016.

other-news

New Siemens ProfiNet - S7-1200 protocol guide

2015-08-26

In this guide we propose, as an example, the design of a simple supervision application Siemens ProfiNet protocol based; this example is a little step towards the design of more complex SCADA applications, but it can be useful for anybody who approaches for the first time to a SCADA, and in particular to Winlog Pro software, to quickly understand how to communicate with external devices (Siemens Simatic S7-1200 PLC).Click here to view the guide.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.07.22

2012-10-18

In these releases following errors have been corrected:- WinlogAn error regarding digital variables reading/writing in modbus protocol has been corrected. This error is present only in 2.07.20 version.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.07.18

2012-07-31

In these releases following features was added:- WinlogAnother vulnerability on TCP port 46824, that would cause a runtime crash, has been corrected.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.07.17

2012-07-17

In these new releases new functions are added:- WinlogChart object revision. Some vulnerabilities to an attack on 46824 TCP port that would cause a runtime crash, have been corrected.- Keyboard BuilderVirtual Keyboard full revision: - Keyboard background bitmap management. - Keyboard opacity management. - Buttons background bitmap management. - Hide/show text on the SHIFT key and special keys. - keyboard management depending on the selected language.- Code BuilderUser account management functions added: AddUser(), RemoveUser(), UserFindFirst(), UserFindNext(), UserFindClose(), UserNameFound(), UserGroupsFound(). TobjGetLButtonDownXY() and TobjGetLButtonUpXY() functions added- ProtocolsOMRON FINS UDP protocol: introduction of read/write HR_UL_,HR_SL_,HR_FL_ ports.Click here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.07.11

2011-12-20

In these new releases new functions are added:- WinlogChart object complete revision. It was fixed a vulnerability for which the inclusion of strings greater than 255 characters, causes a Runtime crash.- Template BuilderAlarmView and HistAlarmView object: introduced the possibility to define which columns are displayed, their order and width.- ReportsPossibility to specify a custom path and file name consists of special strings in which the value will be replaced (day, month, year, hours, minutes, seconds) when the report will be generated.- Code BuilderSendMail function: possibility to specify the port to use to send mail introduced.- ProtocolsSiemens MPI protocol: introduction of read/write numerical ports MD (Merker Long) and MF (Merker Float). ODBC protocol: RestoreChannel() procedure introduced for database reconnection in case of error. ModBus TCP, RTU, ASCII: introduced the possibility to read write double float variables (functions 38,39,48,49). introduced the possibility to read write registers long input variables - Reverse Mode (function 47).Click here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.07.08

2011-07-29

In these new releases new functions are added: - Runtime included the possibility of viewing the gate status filtering based on gate name. - Template Builder introduced a more user-friendly objects management (properties, copy and paste) introduced objects automatic alignment features added ability to change levels of each BkBitmap added the ability to create (and select) a new graphic group in Chart object - Gate Builder introduced the possibility in the event/alarm gate to make a comparison not only with a fixed value (as before) but with another gate. added the possibility to choose a gate filtered by name - Report added the possibility to enable report saving not only on gate trigger but also at Winlog startup - Protocols OMRON FINS UDP protocol: introduced reading and writing of string gates (DM and DMR). Siemens MPI protocol: introduced the possibility to read and write Merker or Flags variables from S7-300/400/1200.Click here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.07.01

2011-01-19

In these new releases new functions are added:- Winlogit is no longer necessary to use the BDE (Borland Datbase Engine) for the DBF files handling. This change solves many installation problems regarding local networks and related the compatibility with other software. It has been corrected a vulnerability to a possible attack on TCP port 46823 to 1000 bytes with a particular sequence of bytes that caused a Runtime crash. - Web ServerOnClick objects property management for the Templates opening added.- Factory Symbol: version 2.5 with new symbols integrated.- Template Builderintroduced detailed view of objects: Chart, HistoricalView, OnLineView, HistAlarmView, DevicesView, OperatorView.- Gate Builderincluded management of the sampling "only at startup" (useful for protocols that have to remain in "listen mode" for example Konnex).- ProtocolsNew Konnex communication protocol (KNX) based on Falcon Library added. New Ethernet-IP communication protocol for SLC500 and MicroLogix series Allen-Bradley PLC added. OMRON FINS protocol in Host Link: introduced the read/write string gates and string gates DMR reading in reverse mode. OMRON FINS UDP protocol: read-write DM_SL (signed long) DM_UL (Unsigned Long) and DM_FL (Float) gates supported. Siemens MPI protocol: modified procedure for communicating with USB adapter - now it is possible to realise up to 16 connections on a single channel. Introduced the possibility to communicate with USB adapter that simulates a virtual COM ( Sielco Sistemi IC 3580-MPIVC). Siemens S7-200 PPI Protocol: introduced the possibility to communicate with USB adapter that simulates a virtual COM ( Sielco Sistemi IC 3580-PPIVC). Protocol and ModbusTCP TCPClient: introduced the possibility to specify the destination address also through HostName as well as IP address.Click here to download new version of Winlog Lite.

other-news

Adapters and converters

2010-11-26

A series of isolated serial converters and adapters are available to link standard PC ports (RS232 COM, USB, Ethernet) with most popular communication interfaces of peripheral devices (RS485, RS422, MPI, PPI); full isolation guarantees the safely running even in the heavy environmental conditions.More informations

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.06.86

2010-10-27

In these new releases new functions are added:- Web server (only Winlog Pro)Bitmap,Label,StatusBar OnClick function added - Template BuilderOnlineAlarms and HistViewAlarms objects: it is possible to set Class 1 and Class 2 filters using Winlog language and refresh alarm list applying the new filters. When the gates linked to Class 3-7 filters change, the alarm list refresh applying the new filters. Label object: "Trasparent","Multiline","Show","Enable" properties added StatusBar object: "Multiline" property added Edit object: "Show","Password mode" properties added DevView object: "Show","Enable" properties added- Code Builderthe following functions were added:Login(),TPageCloseByName()- ProtocolsOMRON FINS in Host Link Protocol: Float DM_FL variables reading and writing introducedClick here to download new version of Winlog Lite.

other-news

Two new Winlog Pro specific licenses for IOlog applications

2010-05-17

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientTwo new specific Winlog Pro licenses are now available for the development and execution of IOlog applications, ie applications that use only SS-3000 modules. The two licenses refer to applications with only one SS-3000 module (W-IOlog-Lite) or with any number of SS-3000 modules (W-IOlog-USB)

other-news

Opening of the new Winlog Lite and Pro Forum

2010-03-25

Sielco Sistemi launched the new Forum Winlog Lite and Pro. This forum is a virtual web based meeting place where Winlog users can exchange an unlimited combination of ideas, help, problems and suggestions. The service is provided by Sielco Sistemi to each member of the community on a free of charge basis. Click here to access the Winlog Lite and Pro Forum

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.06.73

2009-11-19

In these new releases new functions are added:- Web server (only Winlog Pro)SafeComServer Watchdog thread added - Project ManagerNew project configuration functions to allow to Winlog: - to run applications in window mode - to disable restore/maximixe, minimize, resize e move actions - to change taskbar appearence - to hide windows caption- Template BuilderSwitch object: "Mode" property added TabSheet object: "CurrentPage" property is now handled by Code Builder Object120Meter,180Meter,270Meter,VMeter,HMeter,ThermoMeter: "doubleBuffered" property is now available Object HistView,DeviceView,AlarmsView,HistAlarmsView,OperatorView,ReportView: "Window Bkgrnd color" property introduced- Code Builderthe following functions were added:FTPConnect(),FTPDisconnect(),FTPGet(),FTPPut(),TObjFunction(),GetCurrentLanguage()- ProtocolsOMRON FINS in Host Link Protocol added AVEBus protocol and AVE devices added Tutondo protocol added Serial and TCP Modbus RTU protocols modified P_ABSLC5 protocol modifiedClick here to download new version of Winlog Lite.

other-news

SCADA software Winlog Pro provides a new web support

2008-10-31

SCADA HMI Software with Web Support Sielco Sistemi is pleased to announce the new version of its SCADA software Winlog Pro for an easy creation of SCADA applications with a Web Server support, that can be accessed by any Internet Client with a standard browser such as Internet Explorer. Based on Java and LightTPD technologies, the Winlog Pro Webserver solution guarantees the absolute safety of data and the full independence of the Winlog Pro application from the Web Server support running in a protect environment (sandbox). SCADA applications with a Web Server support can be easily created thanks to the new series of W-NET development licenses with capacity increasing from 256 to 65536 tags. Functions, development tools and communication protocols are provided without any restriction by all Winlog Pro development licenses, independently from the capacity (number of tags) or the Web Server support.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.06.60

2008-10-30

In these new releases new functions are added:- Winlog Pro Several inportant changes were introduced in order to support the new Web Server management- Web server (only Winlog Pro)New Web Server Management Integrated HTTP server Java Web Start Tecnology- Project Managerweb project management added- Template BuilderLed object: new kinds of led introduced Led object: transparency introduced Switch object: new kinds of switch introduced Switch object: transparency and resizing introduced Bitmap object: transparent bitmap images visualization added Metafile object: transparent metafile images visualization added ThermalMap objects: new properties added: window background colour, chart backgroun area colour, scale and grid colours Objects Button,Bitmap,MetaFile,StatusBar,Label,VMeter,HMeter,120Meter,180Meter,270Meter,ThermoMeter: now it is possible to specify the operations order on the "OnClick" event; it is also possible to execute up to 5 operation in sequence (i.e. "Open Template" or "Call function") for each single "OnClick" event- Code Builderthe following functions were added: ShellExec() TObjBeginUpdate(),TObjEndUpdate(),TObjSetPropertyBool(),TObjSetPropertyInt(),TObjSetPropertyReal(),TObjSetPropertyString(),TObjSetPropertyUnsigned() to allow template objects parameters modification during Runtime mode- ReportPDF format report addedClick here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.06.50

2008-01-14

In these new releases new functions are added:- Winlog Lite & Pro Several inportant changes were introduced in order to make Winlog compatible with Microsoft Windows Vista. The main change is the possibility to choose the Winlog project area.- HelpHelp conversion from HLP to CHM format- Project Managerpossibility to import/export projects in normal or compressed mode (ZIP) added- Gate BuilderPorte numeriche e porte composte: aggiunta possibilità di convertire automaticamente il valore campionato in valore ingegneristico basandosi sul numero di cifre decimali definito per la porta "Errors Checking" function controls DB integrity and gates/blocks definitions. "Optimize gates sampling" funcion added; it groups gates in blocks for an optimal sampling.- Template BuilderChart object : "Y Grid Divisions" property added- Code Builderthe following functions were added: - CloseKeyboard().- ProtocolsMPI protocol MPI Ethernet communication with S7-200 series PLC added. Click here to download new version of Winlog Lite.

other-news

SCADA software Winlog Pro is now Microsoft Windows Vista compliant

2008-01-14

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientSCADA software Winlog Pro and Lite now works with the new Microsoft Windows Vista operating system. Help files have been rewritten in the new CHM format and a new projects area has been defined. Click here to download new version of Winlog Lite.

other-news

SCADA software Winlog Pro provides new tools for an easy design of animated templates

2007-11-27

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientSupervision of industrial and civil plants requires a realistic and impressive graphic representation; for the development of supervisory (SCADA) applications, it is critical to have the use of tools suitable for the design of animated templates providing a realistic and continuous display of the supervised process.Sielco Sistemi is proud to announce that its supervisory software Winlog Pro has now been improved to provide new development tools for an easy design of animated templates with bitmap and metafile objects. These new tools can use either symbols created by the developer and symbols belonging to Symbol Factory 2.0, the popular library provided with Winlog Pro , that includes over 4,000 manufacturing and industrial objects such as pumps, valves, motors, tanks, PLCs, piping, ISA symbols, etc. The addition of these new tools provides a further enhancement of the graphic performance offered by Winlog Pro SCADA software, already including powerful graphic objects such as circular and linear potentiometers, pointer and linear indicators, thermometers, switches and selectors.Click here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA and Winlog Lite SCADA 2.06.46

2007-11-26

In these new releases new functions are added:- Project Managerstartup template configuration added possibility to write a record in a ".DAT" report from Winlog Code added- Gate Builder"Errors Checking" function controls DB integrity and gates/blocks definitions. "Optimize gates sampling" funcion added; it groups gates in blocks for an optimal sampling.- Template BuilderBitmap object: animation features added (no code required). Meatfile object: animation features added (no code required).- Code Builderthe following functions were added: - SetDateTime() - FileOpenDialog(),FileSaveDialog(). - GetTotalNumGates(),GetTotalDigGates(),GetTotalStrGates(),GetTotalCmpGates(),GetTotalEvnGates(). - GetNumGateGateID(),GetDigGateGateID(),GetStrGateGateID(),GetCmpGateGateID(),GetEvnGateGateID(). - GetNumGateNID(),GetDigGateNID(),GetStrGateNID(),GetCmpGateNID(),GetEvnGateNID().- ProtocolsModbus protocols reverse mode registers reading and writing added. FLOAT type numeric gates reading added. LONG type numeric gates reading added. Numeric gates reading using Modbus function 16 added.Click here to download new version of Winlog Lite.

other-news

Winlog Pro and Winlog Lite 2.06.40

2007-09-03

In these new releases new functions are added:- Template BuilderLed object "Flashing" property added Gadgets objects "Show" property added HtmlHelp object added Licensed Symbol Factory added in Winlog Pro Demo Symbol Factory added in Winlog Lite- Code Builderthe following functions were added: - GetApplicationName - GetDigGateProp and GetStrGateprop- Winlognew Runtime/S1 licence addedClick here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA software now includes Symbol Factory 2.0 library

2007-09-03

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientSielco Sistemi is proud to announce that, following the agreement with Software Toolbox, all Winlog Pro SCADA software development licenses will include Symbol Factory 2.0, the most popular library of industrial automation graphic objects.Symbol Factory 2.0 includes over 4,000 manufacturing and industrial objects such as pumps, valves, motors, tanks, PLCs, piping, ISA symbols, etc. with easy-to-use features for resizing and changing colour, scheme and orientation of objects (bitmap or metafile).Symbol Factory 2.0 provides a further enhancement of the graphic performance offered by Winlog Pro SCADA software, adding a library of symbols to the existing library of powerful graphic objects. The agreement with Software Toolbox acknowledges the continuous efforts of Sielco Sistemi to make Winlog Pro more attractive and competitive. This powerful, low cost and easy to use SCADA software is indeed collecting increasing consensus among Italian and international users and has been selected by leader manufacturers of electronic instrumentation such as Gefran, Ascon, Tecnologic, Siel, Socomec, etc.Click here to download new version of Winlog Lite.

other-news

Winlog Pro and Winlog Lite 2.06.28

2007-06-18

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientIn these new releases new functions are added: - Template Builder the following objects were added: - VSlider - HSlider - Dial - GearDial - VMeter - HMeter - 120Meter - 180Meter - 270Meter - ThermoMeter - RockerSwitch - ToggleSwitch - Code Builder the following functions were added: - NumGateExists(),DigGateExists(),StrGateExists(),CmpGateExists(),EvnGateExists() - PlaySound() to play an audio file even MP3 format - StopSound() to stop an audio file executionClick here to download new version of Winlog Lite.

other-news

Winlog Pro SCADA software includes new graphic options

2007-06-04

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientIn the field of human to machine interfaces (HMI) and supervisory systems (SCADA), there is an increasing request of more attractive and realistic graphic representations. To this purpose Sielco Sistemi has equipped its supervisory software Winlog Pro with a new class of powerful objects that increase the graphic impact and the realism of the SCADA applications. The new library includes circular (Dial, GearDial) and linear (Vslider, Hslider) potentiometers, pointer indicators (120Meter, 180Meter, 270Meter), linear indicators (Vmeter, Hmeter), thermometers (ThermoMeter) , switches and selectors (RockerSwitch, ToggleSwitch). These new graphic objects will make of Winlog Pro SCADA software an ideal solution for the development of operator interfaces with virtual instrumentation. This new release confirms the care of Sielco Sistemi to continuously improve Winlog Pro, the powerful, low cost and easy to use SCADA software selected by many leader manufacturers of electronic instrumentation and collecting increasing consensus among Italian and international users.Click here to download new version of Winlog Lite.

other-news

Winlog SCADA HMI Blog

2007-04-11

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientIn this space we would like to suggest to everyone who needs an easy and low cost SCADA software to test our Winlog Lite. Winlog Lite makes available all development tools and all functions provided by the Winlog Pro software package, but limits the possibility to develop and to run applications up to a max of 24 tags. We are available to discuss with everyone that tested or want to test Winlog Lite.Click here to enter Winlog SCADA HMI Blog.

other-news

Winlog Pro and Winlog Lite 2.06.25

2007-03-26

In these new releases new functions are added: - Protocols new driver SIEMENS MPI Now it is possible to communicate with Siemens Simatic S7 300/400 series PLCs using the USB adapter (PC Adapter USB - Code 6ES7 972-0CB20-0XA0) and a standard ethernet card, in addition to the already supported serial adapter (PC Adapter V5.1 - Code 6ES7 972-0CA23-0XA0). Now it is also possible to read PLC's different types variables in block. - GateBuilder: gates list import/export function in CSV format added. - Code Builder: SendMail() function added in order to allow email sending with or without attachments.

other-news

New SIMATIC S7 driver MPI

2007-03-26

It is available the new version of the communication driver MPI for SIEMENS PLC Series 7. It does not require installation of expensive ProDave Mini. The driver is included in the standard library available in every Winlog version. Now it is possible to communicate with Siemens Simatic S7 300/400 series PLCs using the USB adapter (PC Adapter USB - Code 6ES7 972-0CB20-0XA0) and a standard ethernet card, in addition to the already supported serial adapter (PC Adapter V5.1 - Code 6ES7 972-0CA23-0XA0). Now it is also possible to read PLC's different types variables in block.

other-news

New Winlog Lite SCADA licence for only 49 €

2007-02-16

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientWINLOG LITE is the "Entry level" version of the SCADA software WINLOG offered by SIELCO SISTEMI to its customers to allow an evaluation of the potentiality and the simplicity of use of the package; WINLOG LITE is also a powerful and low cost solution for creation of small supervisory applications. WINLOG LITE makes available all development tools and all functions provided by the standard WINLOG software package, but limits the possibility to develop and to run applications up to a max of 24 tags.

other-news

Winlog Pro e Winlog Lite SCADA 2.06.24

2007-02-15

The main changes in this release are related to communication protocols: - Now it is possible to use up to 20 (instead of 9) COM ports with MODBUS RTU and ASCII communication protocols. - Now it is possible to set serial port parameters in REMOTE MODBUS RTU AND ASCII protocols configuration

other-news

Winlog Pro and Winlog Lite 2.06.21

2007-01-11

The main news in this release are related to the historical files management. Now it is possible to create a single file for each kind of gate (numeric, digital etc.) in DB4 format (as before) or to create a binary historical file for each gate. This second possibility allows to handle local or remote (TCP/IP) historical data faster than before (charts and tables). It is also possible to create a CSV file for each "record on DB" gate containing its historical variations. New features are also added to Template Builder: - now it is possible to show the print button and the print options button for HistoricalAlarmView and OperatorView objects. User will be able to print historical data included in the choosen time range. - now it is possible to show the CSV save button and the CSV option button for HistoricalAlarmView and OperatorView object.User will be able to export historical data included in the choosen time range in a CSV format file. - a new HistoricalView object for historical data view in a table mode has been added. - STAY ON TOP property templates added. - now it is possible to place objects over a BackGroundBitmap. - now it is possible to copy/paste a BackGroundBitmap. - now it is possible to copy a bitmap or a metafile into another one. - now the Property Editor is always on top. - object multiselection for object moving, copiing, pasting or cutting has been added. - now it is possible to select the default server from which read historical data (using TCP/IP protocol) for Chart, OperatorView and HistView objects. - chart scale autorange has been modified in order to show vertical axis scale with integer values. New features are also added to Multilanguage editor: - now it is possible to choose the text classes to insert in the multilanguage file.

other-news

Quality Certification ISO 9001:2000 (VISION 2000)

2006-12-28

Sielco Sistemi developes Winlog SCADA/HMI with OPC ClientSielco Sistemi proudly announces the attainment of the quality certificate ISO 9001:2000. Such certificate currently represents the new and worldwide recognized reference for the quality control certification in any productive sector and for any organisation size.

other-news

Winlog and Winlog Lite 2.06.18

2006-10-03

In these new releases new functions are added: - Protocols Four new formats for string ports reading (Modbus RTU and Modbus RTU TCP) added - Project Manager Project password protection added; who designs the project can decide to protect it. Only using the right password it is possible to access to the project using Gate Builder, Template Builder and Code Builder - Code Builder: New date/hour instructions added: DateTimeToSeconds(), GetDayFromSeconds(), GetMonthFromSeconds(), GetYearFromSeconds(), GetHourFromSeconds(), GetMinuteFromSeconds(), GetSecondFromSeconds(). New devices handling instructions added: DeviceEnableCommunication(,,,), DeviceName(,), GetDeviceRxErrors(,), GetDeviceTxErrors(,), IsDeviceCommunicationEnabled(,), IsDeviceCommunicationKo(,), ResetDeviceRxErrors(,), ResetDeviceTxErrors(,). New instructions for gates handling added: GetNumGateValueAsString and GetCmpGateValueAsString. New logic instructions added: BitAnd(), BitOr(), BitXor(), BitNot(). - Template Builder "Autorange" property in Chart object added %X.*lf notation in Label, StatusBar and Gauge objects added in order to show the gate value decimal digits specified in the gate definition properties. MultiTemplate windows modified: now it is possible to specify the objects order in MultiTemplate creation. - Application Builder Now it is possible to build the application in which Application Builder automatically will replace $Channel, $Device, $Prefix variables in the funtions called from templates with the device configuration data.

other-news

Now you can buy Winlog Lite using your American Express credit card

2006-07-17

Sielco Sistemi relies on BANKPASS Web services for credit card payments. BANKPASS Web allows online payment with Visa, Mastercard,Maestro or American Express. The payment system uses the Secure Sockets Layer protocol (SSL) with an encryption key length of 128-bits (the highest level commercially available) to ensure the highest transaction security. Moreover, credit card data are provided directly and exclusively to the payment service administrator; Sielco Sistemi is only informed about the result of the transaction and has no involvement in the process.

other-news

New Winlog Pro quick guides available

2006-05-23

Today Winlog Pro quick guides are available in the new Application notes area in the Download section: - Getting Started - Creating a simple Modbus protocol application - Getting Started - Creating a simple Siemens MPI protocol application - Getting Started - Creating a simple Siemens PPI protocol application - Getting Started - Creating a simple Omron Sysmac protocol application - Getting Started - Creating a TCP-IP protocol Client application

other-news

Winlog Pro and Winlog Lite 2.06.14

2006-04-27

These new releases include ODBC client that allows communication to external database. Click here to download new version of Winlog Lite.

other-news

New ODBC Client interface for Winlog Pro and Winlog Lite now available

2006-04-27

Open Database Connectivity (ODBC) provides a standard software API method for using database management systems (DBMS). The ODBC specification offers a procedural API for using SQL queries to access data. Winlog Pro and Winlog Lite interface ODBC client through user defined SQL strings to create SELECT, UPDATE and APPEND queries towards standard database.

other-news

Winlog and Winlog Lite 2.06.13

2006-03-23

In these new releases has been corrected a bug for which, with particular WINDOWS XP installations, SIMATIC S7 MPI protocol do not function correctly. Click here to download new version of Winlog Lite.

other-news

Winlog and Winlog Lite 2.06.12

2006-03-17

In these new releases new communication protocols are added: - OMRON FINS UDP ETHERNET communication protocol added - COOP. BILANCIAI EV2001 communication protocol added - CR MAGNETICS DATA STREAM communication protocol added - DATA STREAM CRD5110,CRD5150,CRD5170 devices added - BCD format in numeric gates added

other-news

New EV2001 TERMINAL (COOP BILANCIAI) communication protocol

2006-03-16

COOP. BILANCIAI EV2001 communication protocol is supported by the following devices: - EV2001 TERMINALS

other-news

New DATA STREAM (CR MAGNETICS) communication protocol

2006-03-16

CR MAGNETICS DATA STREAM communication protocol is supported by the following devices: - DATA STREAM CRD5110 (Winlog and Winlog Lite device developed) - DATA STREAM CRD5150 (Winlog and Winlog Lite device developed) - DATA STREAM CRD5170 (Winlog and Winlog Lite device developed)

other-news

New OMRON FINS UDP ETHERNET communication protocol

2006-02-27

OMRON FINS UDP ETHERNET communication protocol is supported by the following PLC: - OMRON CJ series - OMRON CS series - OMRON CV series

other-news

Winlog and Winlog Lite 2.06.10

2006-02-03

In these new releases virtual keyboard is added: - Keyboard Builder and virtual keyboard added - Code Builder "Keyboard()" function added - "Keyboard" property in Edit object added (automaticaly virtual keyboard recall)Click here to download new version of Winlog Lite.

other-news

New OPC Client interface for Winlog and Winlog Lite now available

2006-01-31

OPC (OLE for Process Control) is an industrial standard, created by main worldwide leading automation manufacturers, that allows data exchange between different software components without need of any special adjustment. Winlog OPC Client driver supports data access (DA) to OPC servers DA 1.0 and 2.0; it can interface both local OPC Servers (through COM objects) and remote OPC Servers (through DCOM objects) located on different PCs linked via a local network.

other-news

Winlog and Winlog Lite 2.06.09

2006-01-31

In these new releases the new OPC Client driver is added: OPC Client driver support data access (DA) to OPC servers DA 1.0 and 2.0 . It can connect to local OPC servers through COM object or to remote OPC servers (in the local network) through DCOM object.Click here to download new version of Winlog Lite.

other-news

Now you can buy Winlog Lite using your credit card

2005-12-21

Sielco Sistemi relies on BANKPASS Web services for credit card payments. BANKPASS Web allows online payment with Visa, Mastercard or Maestro. The payment system uses the Secure Sockets Layer protocol (SSL) with an encryption key length of 128-bits (the highest level commercially available) to ensure the highest transaction security. Moreover, credit card data are provided directly and exclusively to the payment service administrator; Sielco Sistemi is only informed about the result of the transaction and has no involvement in the process.

other-news

Winlog 2.06.06

2005-12-07

In this new version two new Code Builder instructions have been added: - ReportInsertHistoricalAlarmsRTF - ReportInsertHistoricalAlarmsTXT An easy way to insert Alarms/Events historical view in reports. Moreover now it is possible to insert parameters into functions linked to OnClick event in Template Builder objects.

other-news

Winlog Lite 2.06.06

2005-12-07

In this new version two new Code Builder instructions have been added: - ReportInsertHistoricalAlarmsRTF - ReportInsertHistoricalAlarmsTXT An easy way to insert Alarms/Events historical view in reports. Moreover now it is possible to insert parameters into functions linked to OnClick event in Template Builder objects.Click here to download new version of Winlog Lite.

other-news

Winlog 2.06.04

2005-11-09

In this new version it is possible to control users access to each Template Object: - Edit, RadioButton, CheckBox, Switch, ComboBox, FileListBox, Button - Bitmap, Metafile, StatusBar, UdDown Following templates have been modified: - OperatorView - HistView TCP/IP server has been modified.

other-news

New SIMATIC S7 driver PPI

2005-10-20

It is available the new communication driver MPI for SIEMENS PLC Series 7. The driver is included in the standard library available in every Winlog version. It requires the SIEMENS SIMATIC S7 Serial-MPI adapter model no. 6ES7901-3CB30-0XA0.

other-news

New Raw ASCII Output driver

2005-10-05

It is available the new serial communication driver Raw ASCII Output that allows to send ASCII char strings to devices using serial ports. It is possible to send up to 80 characters for each command. The driver is included in the standard library available in every Winlog version.

other-news

Winlog Lite 2.06.03

2005-08-29

This release fixes some bugs relative to template "LABEL" object and remote historical files reading.

other-news

Sielco Sistemi moves in its new office

2005-07-27

Sielco Sistemi moves in its new office at the following address: via Roma, 24 22070 Guanzate (CO) Italy You can contact us using the following phone numbers: Tel: +39 031899671 Fax: +39 0313528682

other-news

New SIMATIC S7 driver MPI

2005-07-05

It is available the new communication driver MPI for SIEMENS PLC Series 7. It does not require installation of expensive ProDave Mini. The driver is included in the standard library available in every Winlog version. It requires the SIEMENS SIMATIC S7 Serial-MPI adapter model no. 6ES7972-0CA23-0XA0.

other-news

Winlog Lite

2005-07-05

WINLOG LITE is the "Entry level" version of the SCADA software WINLOG offered by SIELCO SISTEMI to its customers to allow an evaluation of the potentiality and the simplicity of use of the package; WINLOG LITE is also a powerful and low cost solution for creation of small supervisory applications. WINLOG LITE makes available all development tools and all functions provided by the standard WINLOG software package, but limits the possibility to develop and to run applications up to a max of 48 tags.

other-news

New web-site opening

2005-05-19

SIELCO SISTEMI is proud to present his new web-site. You can find complete HMI and SCADA solutions. Our offer is directed to end-users, OEM and system integrators. Soon will be available a wide download area, in which you will be able to find the new shareware version of the famous SCADA software Winlog (Lite version).

other-news

Support contracts

2005-05-18

All customers whose free assistance period is expired are invited to subscribe support contracts. More info on support page.

other-news

Version 2.06.00 under test

2005-05-17

Our laboratories are testing the version 2.06.00 of our software Winlog. Soon will be available list of bug-fix and new features introduced in the new version.

other-news

New SIMATIC S7 driver in progress

2005-05-08

Soon will be available a new communication driver for SIEMENS PLC Series 7. It does not require installation of expensive ProDave Mini.